Home Shop EVSE ACT100 & DCT350 – AC & DC Test Systems (Cat. 5000)

ACT100 & DCT350 – AC & DC Test Systems (Cat. 5000)

ACT100 & DCT350 – AC & DC Test Systems (Cat. 5000)

Made in USA

The ACT100 (3-Phase AC Test System) and DCT350 (DC Test System) are high-accuracy reference standards and digital waveform generators designed for precise EVSE calibration, compliance testing, and performance validation.

Features:

  • Universal Calibration: Supports AC (ACT100) & DC (DCT350) EVSE testing
  • Industry-Leading Accuracy: Voltage, current, and energy measurements with ±0.05% precision
  • Advanced Waveform Generation: Customizable waveforms with harmonic analysis up to the 50th order
  • Seamless Connectivity: Ethernet-enabled remote calibration and monitoring
  • Designed for Compliance: Ensures conformance with industry standards

Product Description:

The ACT100 & DCT350 are engineered to provide unparalleled accuracy and efficiency in EVSE testing. Built for laboratory and manufacturing environments, these rack-mounted systems provide real-time waveform generation, harmonic analysis, and automated calibration to ensure accuracy across AC and DC electric vehicle charging systems.

Specifications:

ACT-100:

Unit Details
Digital Waveform Generator Capabilities:
Channels Three voltage and three current channels
Synthesizer Fundamental frequency: 45 to 65 Hz (0.01 Hz resolution)
Sinusoidal (THD < 0.4%) (< 0.1% typical)
ANSI harmonics and custom harmonics
Current 0.1A – 100A rms, 0.01A increment, 0° – 360° phase (0.001° increment), 0.2% accuracy, 1V compliance voltage, open circuit protection
Voltage 30V – 350V L-N / 0V – 700V L-L, 0.01V increment, 0° – 360° phase (0.001° increment), 0.2% accuracy, 100VA output power, short circuit protection
Integrated Reference Standard:
Accuracy Phase: ±0.01°, Real/Apparent/Reactive Energy: ±0.04%
Measurement Range 60 – 350 Vac, 0.25 – 80 Aac @ 60Hz, @ 1.0 PF
Other Measures to 50th Harmonic, Time & Frequency domain measurements
Physical:
Size 25.54”L x 25.62”W x 75.5”H, 15” shelf
Screen 21” screen
Input Power 120V, 8A, 60Hz
Cabling DB9 pulse cable, CCS1 AC calibration cable, NACS AC calibration cable, AC return cable, External reference calibration
Interfaces Ethernet, DB9 header for synchronization, RJ45 jack for comms

DCT-350:

Unit Details
Digital Waveform Generator Capabilities:
Channels Two voltage and two current channels
Voltage 1V – 1000V L-L (center tapped to GND), 1V increment, 1% accuracy, 100VA output power
Current 1A – 630A rms, 1A increment, 1% accuracy, 2V compliance voltage
Integrated Reference Standard:
Accuracy Voltage: ±0.05%, Current: ±0.05%, Energy: ±0.1%
Measurement Range 100 – 1000 Vdc, 20 – 600 Adc
Other Time & Frequency domain measurements
Physical:
Size 25.54”L x 25.62”W x 75.5”H, 15” shelf
Screen 21” screen
Input Power 240V, 30A, 60Hz
Cabling DB9 pulse cable, CCS1 DC calibration cable, NACS DC calibration cable, DC return cable
Interfaces Ethernet, DB9 header for synchronization

Equipment Documentation:

Request a Quote