Made in USA

AC CableThe MiTM is a cable with a Staubli interface on one side and an EVSE interface on the other. It is intended to be used with a T4000 or T4350 in a man-in-the-middle configuration.

Features:

  • Internal MCU to communicate with T4000 / T4350
  • Protective Cap for Staubli terminals

Available Configurations:

  1. DC Cables:
    • MM-CCS1-DC-350: DC 350A Cable, CCS1 Adapter
    • MM-NACS-DC-350: DC 350A Cable, NACS Adapter
  2. AC Cable:
    • MM-CCS1-AC-80: AC 80A Cable, CCS1 Adapter

Product Description:

The Man-in-the-Middle (MiTM) Cable is a high-precision, real-time data capture solution designed for use with TESCO’s T4000 and T4350 EVSE Test Systems. Featuring a Staubli interface on one side and an EVSE adapter on the other, this specialized cable allows direct man-in-the-middle (MiTM) testing of CCS1 and NACS AC/DC charging systems, enabling manufacturers, service providers, and regulatory bodies to monitor, validate, and optimize EVSE performance under real-world conditions.

The MiTM Cable is available in multiple configurations, ensuring compatibility with a wide range of EV charging systems.

Real-Time Data & Safety Features

Designed for precision testing, the MiTM Cable integrates an internal MCU, facilitating seamless communication with T4000 and T4350 systems.

  • Internal MCU for Direct T4000/T4350 Communication – Captures real-time test data
  • Integrated Thermistors – Monitors temperature changes for safe operation
  • Protective Staubli Terminal Cap – Ensures secure connections and extended durability
  • Durable, Compact & Field-Ready

Specifications:

DC Cables:

Unit Details
MM-CCS1-DC-350 DC 350A Cable, CCS1 Adapter
Interface 1 CCS1 (DC+, DC-, GND, CP)
Interface 2 TESCO Staubli interface (DC+, DC-, GND, CP, VMain, RS-485)
MM-NACS-DC-350 DC 350A Cable, NACS Adapter
Interface 1 NACS (DC+, DC-, GND, CP, PP)
Interface 2 TESCO Staubli interface (DC+, DC-, GND, CP, VMain, RS-485)
Voltage 1000V DC
Current 350A sustained, 650A for <5 minutes
Power 0 to 350kW sustained (650kW for <5 minutes)
Length 78” (6.5 Ft)
Weight 21 lbs.
Thermistors To measure temperature
Operating Temp -4°F to 122°F (-20°C to 50°C)
Storage Temp -22°F to 140°F (-30°C to 60°C)

AC Cable:

Unit Details
MM-CCS1-AC-80 AC 80A Cable, CCS1 Adapter
Interface 1 CCS1 (L1, L2, GND, CP, PP)
Interface 2 TESCO Staubli interface (L1, L2, GND, CP, VMain, RS-485)
Voltage 240V AC
Current 80A
Power 0 to 19.2kW
Length 78” (6.5 Ft)
Weight 6 lbs.
Internal MCU Communicates with T4000 / T4350

Why Choose the MiTM Cable?

  • Seamless Integration with T4000 & T4350 – Plug-and-play operation for real-time EVSE data capture
  • Supports Both AC & DC Testing – Compatible with CCS1 and NACS charging systems
  • Industry-Leading Power Handling – Up to 1000V DC & 350A sustained, 650A peak
  • Designed for Accuracy & Safety – Integrated MCU, thermistors, and protective cap